ASTM C289 PDF

ASTM C – 07 Standard Test Method for Potential Alkali-Silica Reactivity of Aggregates (Chemical Method) – Download as PDF File .pdf), Text File .txt) or. All the Controls products ASTM C standard. Enter now!. ASTM C Standard Test Method for Potential Alkali-Silica Reactivity of Aggregates (Chemical Method). Lab ID: Use A rapid indication of potential alkali.

Author: Disida Dogis
Country: Serbia
Language: English (Spanish)
Genre: Life
Published (Last): 11 August 2014
Pages: 10
PDF File Size: 3.11 Mb
ePub File Size: 19.4 Mb
ISBN: 853-5-63960-933-5
Downloads: 94827
Price: Free* [*Free Regsitration Required]
Uploader: Mikalrajas

Please help us to share our service with your friends. The author suggests methods of accelerating tests; the simple gel pat test has been run at an elevated temperature of storage with reasonable success. Figures; Photos; References; Tables; Pagination: NOTE 3—An over-pulverized sample satm not produce the correct chemical test results. The mass fraction ranges of the elements listed have been established through cooperative testing 2 of reference astm e pdf.

Record the total amount of time during which the vacuum is applied as the filtration time; make every effort to achieve an equal filtration time for all samples in a set, by uniformity of procedure in the assembly of the filtration apparatus and the packing of the solids in the crucible. This standard has been approved for use by agencies ast the Department of Defense. For the other test solutions, astn can be eliminated.

Eylüllab Test Equipment

Dissolved Silica by the Gravimetric Method 8. Essentially, ASR distress is caused when aggregates containing unstable silica minerals react with cements having high alkali content, to form a gel. Current edition approved Aug. Astm c standard test method for potential alkalisilica reactivity of aggregates chemical method standard number. Since there appears to be an increased concern about ASR, I thought it might timely to discuss alkali-aggregate reactions AAR in concrete.

TOP Related Posts  8751 MICROCONTROLLER EPUB DOWNLOAD

astmm

Astm c289 free download

To download astm e pdf, click on the download button download it further assumes familiarity with flashing and sealing, glazing procedures, finishes where applicable, asstm an understanding of the fundamentals of construction that affect the installation astm e pdf these units. We need your help to maintenance this website. The best way to control ASR is to ensure that you are not using reactive aggregates.

The mass fraction ranges of the astm e pdf listed have been established through cooperative testing 2 of reference materials. Even though aggregates may contain reactive forms of silica, there will be no alkali-silica reaction if the alkali content of the cement is low, or if the finished concrete product is not exposed to excess moisture.

Sims, I Publication Date: Astm c compressive strength hydraulic cement mortars. These aggregates should be considered to indicate a potentially deleterious degree of reactivity until the innocuous character of the aggregate is demonstrated by service records or by supplementary tests in accordance with the provisions of Test Methods CCor Cas applicable.

Allow the solution to stand for 5.

ASTM-C-289-Potential Alcali-Silice Reactivity of Aggregates.pdf

Do not xstm more than g over a mm diameter sieve at one 3 C — 03 time. Approved July 10, The astm charges so every site that offers pdfs also charges.

Use a porcelain Gooch crucible see Note 4 with a disk of rapid, analytical-grade filter paper cut to fit the bottom of the crucible, setting the crucible in a rubber crucible holder in a funnel. Containers with wall thickness not less than 0.

TOP Related Posts  CONTROL ESTADISTICO DE CALIDAD Y SEIS SIGMA EPUB DOWNLOAD

Size px x x x x Unless otherwise indicated, all reagents shall conform to the specifications of the Committee on Analytical Reagents of the American Chemical Society, where such specifications are available. Two problems often occur: We need your help!

Do not use a standard silica solution older than 1 year, since dissolved ionic silica in such a solution slowly polymerizes, causing spuriously low photometric readings see Note 2. These should include full-face shields, rubber aprons, and gloves impervious to HF.

NOTE 6—The mass of the empty crucible may be determined if one wishes to know the magnitude of impurities in the residue of SiO2. Retain the other three quarters of the sample for further testing if desired. Details are also given of the chemical test ASTM C and sources of possible error are indicated. Please copy and paste this embed script to where you want to embed Embed Script.

The results from this test method can be obtained quickly, and, while not completely reliable in all cases, they can provide useful data. This second evaporation is necessary only when determining the concentration of the standard sodium metasilicate solution in 5.

Allow the solution to stand for 15 min at room temperature.